Detailed Explanation of the Calibration Steps for the JSCW-50 Split-type Submersible Level Transmitter: Latest Operation Guide for 2023
Added to Favorites:125

As a professional supplier in the field of flow control equipment, Xi'an Shenghongchuang Instrument Co., Ltd. brings you the latest 2023 edition of the JSCW-50 split-type submersible level transmitter calibration guide. This article provides a detailed analysis of the calibration steps for this transmitter model, while also covering the working principles, troubleshooting, and wiring methods of common models such as YWKT-150 and XY530BA, helping distributors and end users master precise level measurement technology.


I. Core Calibration Steps for the JSCW-50 Split-type Submersible Level Transmitter

Calibration is the key step to ensuring the measurement accuracy of a level transmitter. The JSCW-50 split-type submersible level transmitter should be operated according to the following process:

  1. Zero calibration: Place the sensor under standard atmospheric pressure and adjust the output signal to 4mA through the HART protocol
  2. Full-scale calibration: Apply the rated pressure value (such as 10MPa) and adjust the signal to 20mA
  3. Linearity verification: Measure the error values at 25%, 50%, and 75% range points respectively, which should meet the ±0.5%FS accuracy grade requirements
  4. Temperature compensation: Conduct a temperature drift test in an environmental chamber at -20℃~80℃

II. Comparative Analysis of Mainstream Model Technologies

ModelMeasuring RangeAccuracy ClassMedium Temperature
JSCW-500-50m±0.5%FS-20~80℃
YWKT-1500-150m±0.25%FS-40~125℃

III. Typical Troubleshooting Solutions

For common issues with the KZY-KO-LAG split-type submersible level transmitter:

  • Signal drift: Check whether the cable shield layer is properly grounded; it is recommended to use a twisted-pair shielded cable
  • Display abnormality: When using the XY530BA split-type submersible level transmitter, confirm that the supply voltage is stable at 24VDC±10%
  • Diaphragm fouling: Selecting the XEW503 model made of PTFE can effectively solve corrosive media issues

IV. Why Choose Shenghongchuang Instrument

As a national high-tech enterprise, we provide:

  • The full product series has passed CE certification and RoHS testing
  • The self-developed YH800 split-type submersible level transmitter adopts a military-grade signal processing chip
  • A 72-hour rapid response mechanism, providing on-site calibration services

Call 029-84563217 now to obtain the XEW502 split-type submersible level transmitter specification model list and the latest quotation.