News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

HM20-1-A1-F2-W2 Pressure Transmitter Installation Guide: A Pitfall-Avoidance Manual for Diffused Silicon Sensor Installation
Added to Favorites:125
HM20-1-A1-F2-W2 Pressure Transmitter Installation Guide: A Practical Handbook for Avoiding Pitfalls in Diffused Silicon Sensor Installation

As a key device in industrial automation control, the correct installation of the diffused silicon sensor in the HM20-1-A1-F2-W2 pressure transmitter directly affects measurement accuracy and equipment service life. This article addresses common problems encountered by contract executors during on-site installation, and provides a detailed analysis of the installation essentials for models such as PT-509-L and KYXT1200-SM5DGZ, helping you avoid risks such as sensor damage and data drift caused by improper installation, and ensuring smooth project acceptance.


I. Core Installation Principles for Diffused Silicon Pressure Transmitters

Diffused silicon sensors are widely used in pressure transmitters such as PT-509-L and KYXT1200-SM5DGZ due to their high sensitivity and stability. During installation, the following three core principles must be followed:

  • Media compatibility verification: Confirm that the measured medium is compatible with the 316L stainless steel diaphragm and sealing materials of HM20-1-A1-F2-W2 to avoid sensor failure caused by corrosive liquids
  • Mechanical stress elimination: During installation, use a torque wrench to control the tightening force (usually 20-30N·m) to prevent excessive stress from causing cracks in the ceramic substrate of model YM-YM4889
  • Temperature gradient control: Under high-temperature operating conditions such as HB-35C-DC24V, the temperature difference between the sensor and the pipeline must be kept ≤5℃ to avoid zero-point drift caused by thermal expansion

According to the requirements of the ISO 9001 quality management system, all ZJ-1P-12PV series products are temperature-compensation calibrated before leaving the factory, but improper installation may still cause the calibration parameters to become invalid.


II. Installation Scheme Design Under Different Operating Conditions

1. Liquid Pressure Measurement Scenario

For the application of model DG2112-YY in chemical processes, the following installation configuration is recommended:

Installation LocationPipeline requirementsProtective Measures
At 3-5 pipe diameters from the pump outletStraight pipe section for DN50 and aboveInstall the dedicated HQ-HQ1000 pulse damper
On the side of the bottom of the storage tankInstall at a 15° inclinationConfigure KYB2003G05M1PXC2-I anti-crystallization isolation diaphragm

2. Gas Pressure Monitoring Scenario

When installing model JVPL-JVPL10 in natural gas pipelines, special attention should be paid to:

  • Install at the top of a vertical pipeline to avoid condensate accumulation
  • Equip with a 0.1μcm precision filter (compliant with GB/T 17213 standard)
  • Apply IP65 sealing treatment to the electrical interface of HM20-1-A1-F2-W2

III. Typical Installation Errors and Solutions

According to the field service data of Xi'an Shenghongchuang Instrument Co., Ltd., 80% of after-sales issues originate from the following installation mistakes:

  1. Vibration coupling issue: A PT-509-L transmitter at a power plant was installed directly on a vibrating pump body, resulting in fatigue failure of the diffused silicon chip. Solution: add rubber vibration-damping pads, and the vibration amplitude must be controlled below 0.1mm/s
  2. Electrical interference issue: KYXT1200-SM5DGZ experienced signal fluctuation near a frequency converter. Twisted shielded cable (AWG18 and above) must be used, and the distance from power cables must be ≥30cm
  3. Lack of overload protection: The diaphragm of YM-YM4889 ruptured under pressure shock conditions. A matching snubber valve should be installed, and the shock pressure must not exceed 150% of the measuring range

IV. Key Verification Steps After Installation

After completing the installation of the HM20-1-A1-F2-W2 pressure transmitter, the following verification procedures must be carried out:

  • Zero-point calibration: Use a HART communicator under atmospheric pressure to check the zero-point output (4mA±0.02mA)
  • Step response test: Rapidly switch the valve to observe the output response time of DG2112-YY (should be ≤50ms)
  • Long-term stability monitoring: Continuously record the output fluctuation of HB-35C-DC24V for 72 hours (allowable deviation ≤0.1%FS)

For customized models such as JVPL-JVPL10, it is recommended to keep photos of the installation process and torque records as an important part of the acceptance documents.


V. Professional Support and After-Sales Service

Xi'an Shenghongchuang Instrument Co., Ltd. provides the following for all ZJ-1P-12PV series products:

  • Free installation technical guidance (400-xxx-xxxx)
  • On-site calibration service for model HQ-HQ1000 (48-hour response)
  • A three-year warranty commitment for KYB2003G05M1PXC2-I

Our engineering team holds ASME B40.9 certification and can provide you with complete installation solutions compliant with API 675 standards.


Take action now: Download the "White Paper on Diffused Silicon Pressure Transmitter Installation Specifications", or contact our technical consultants to obtain a customized installation solution for HM20-1-A1-F2-W2. Ensure your project passes acceptance in one go, and avoid schedule delays and cost losses caused by installation issues.

Submit