News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

HK-613 Pressure Transmitter Buying Guide: 3 Key Performance Indicators of Diffused Silicon Sensors
Added to Favorites:125

Introduction

In the field of industrial flow control, the selection of the HK-613 pressure transmitter directly affects system stability. As a professional manufacturer of diffused silicon sensors, Xi'an Shenghongchuang Instrumentation will analyze the 3 key performance indicators you must consider when purchasing diffused silicon liquid and gas pressure sensors, helping you quickly match the precise requirements of models such as BTL-BTL70 and CYB-20SA.


1. Accuracy and Stability: The Core Indicators of Diffused Silicon Sensors

The accuracy of diffused silicon pressure sensors directly determines the measurement reliability of the HK-613 pressure transmitter. According to ISO 9001 standards, high-quality diffused silicon sensors should meet the following requirements:

  • Non-linearity error ≤0.1%FS: ensure that models such as BTL-BTL70 maintain linear output within the full scale range
  • Repeatability error ≤0.05%: CYB-20SA needs to maintain data consistency in multiple measurements
  • Temperature drift coefficient ≤0.01%/℃: cope with industrial environmental fluctuations from -40℃~125℃

Xi'an Shenghongchuang's SK1151-33X series uses military-grade silicon chips and has passed 2000-hour aging tests, with its independent linearity reaching 0.05%, far exceeding the industry average.


1.1 Long-term Stability Verification Methods

It is recommended to verify the stability of models such as LYB-LYB3008 through the following methods:

Test ItemStandard RequirementsTest Data (KYBX-KYBX)
Annual Drift≤0.2%FS/year0.08%FS
Mechanical Shock100g/11msZero Shift<0.03%

2. Media Compatibility and Sealing Design

Models such as DET-131 need to adapt to different operating media, and special attention should be paid to the following when selecting them:

  1. Wetted material: 316L stainless steel diaphragm can withstand corrosion from acidic and alkaline media
  2. Sealing grade: IP68 protection and welded sealing structure ensure long-term leak prevention
  3. Pressure port: interfaces such as G1/4" and NPT1/2 need to match the existing piping system

For high-pressure environments such as injection molding machines, it is recommended to use domestic TLH slider electronic ruler displacement sensor together as a set. Its conductive plastic film material and IP67 sealing grade can perfectly match the installation requirements of HK-613.


2.1 Special Media Handling Solutions

Application recommendations for ND-1 in the following scenarios:

  • Viscous media: install a diaphragm isolator
  • High-temperature steam: configure heat dissipation fins and capillary tubes
  • Corrosive liquids: use Hastelloy wetted parts

3. Signal Output and System Integration

The signal processing capability of models such as KD-KD201 directly affects the accuracy of the control system:

  • Output type: 4-20mA/0-10V signals need to match the PLC acquisition module
  • Response time: rapid response of <1ms is suitable for dynamic pressure monitoring
  • EMC protection: passed IEC 61000-4-3 Level 4 electromagnetic compatibility testing

When used together with TLH series displacement sensors, it is recommended to adopt an RS485 bus architecture, and its wide operating voltage design of 5-24VDC can simplify the power supply system.


Summary and Action Recommendations

When purchasing diffused silicon pressure transmitters such as HK-613/JYB-KO-M, it is recommended to prioritize: 1)measurement accuracy of 0.05 class or above; 2)sealing protection of IP67 or above; 3)standardized signal output interfaces. As a sensor manufacturer certified to ISO 17025, Xi'an Shenghongchuang can provide full-process services from selection consultation to on-site commissioning.

Contact our technical team now to obtain customized solutions and the latest technical white papers for models such as BTL70 and CYB-20SA.

Submit