As a core component of industrial automation control, the HG-S3 pressure transmitter relies on the correct installation and commissioning of its diffused silicon sensor, which directly affects measurement accuracy. Focusing on the core needs of technical evaluation personnel, this article provides a detailed analysis of 5 key operating steps for PT124B-210, DG1300, and other series products, helping you quickly master the key points of on-site application for models such as VEGABAR-GV3.
Diffused silicon pressure sensors measure pressure through the semiconductor piezoresistive effect, with the core being a Wheatstone bridge formed by diffusion on a silicon diaphragm. When medium pressure acts on the diaphragm, the resistance value changes, causing the bridge output signal to change. Taking the PT124B-210 series as an example, it uses an M14 threaded interface, with a measuring range covering 0-25MPa, making it suitable for most industrial scenarios.
Key selection parameters:
Before installing models such as SY-PG1300-1.6MPa-GB, a systematic inspection is required:
Special reminder: When installing the PT-PT300 series, keep the process connection axis consistent with the direction of gravity to avoid lateral stress affecting measurement accuracy.
1.Threaded connection specification: For the PT124B-210-100MPa-G1/4 model, the installation torque should be controlled at 15-20N·m, as excessive tightening may cause diaphragm deformation
2.Selection of sealing materials:
3. Post-installation inspection: Use a helium mass spectrometer for airtightness testing, and the leakage rate should be <1×10-6 mbar·L/s
1.Wiring method: HG-S3 provides 4-20mA two-wire output, and the wiring terminals must comply with the IEC 60947 standard
2.Zero-point calibration: Under no-load conditions, adjust the zero-point output of DG1300-BZ-A-2-0.1 (corresponding to 4mA) through the HART protocol
3.Range verification: Use a pressure calibrator to apply full-scale pressure (such as the 25MPa point of PT124B-210-25MPa-M14), and confirm that the 20mA output deviation is ≤±0.5%
Common problem handling:
It is recommended to carry out preventive maintenance every 6 months, including:
In the petrochemical field, the VEGABAR-GV3 pressure transmitter has been successfully applied to pressure monitoring of hydrogenation reactors, and its features include:
Selection decision tree:
Correct installation and commissioning are key to ensuring the long-term stable operation of diffused silicon pressure sensors. As a professional pressure transmitter manufacturer, Xi'an Shenghongchuang Instrument Co., Ltd. provides technical consultation and on-site support services for the full range of products from PT124B to DG1300. Our engineering team has more than 10 years of industry experience and can provide you with:
Contact our technical consultants now: Call 029-XXXXXXX to obtain the complete technical manual for the HG-S3 pressure transmitter, or visit the official website to view detailed parameters and certification documents for products such as PT-PT300.