News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

GPD-GPD10 Pressure Transmitter Field Test: How Does a Diffused Silicon Liquid and Gas Pressure Sensor Perform?
Added to Favorites:125

Analysis of the Core Performance of Diffused Silicon Pressure Sensors


The GPD-GPD10 pressure transmitter adopts diffused silicon technology to realize pressure signal conversion through the semiconductor piezoresistive effect. In actual testing, its 0.25 class overall error accuracy can stably maintain a temperature drift performance of ±0.05%FS/℃, making it particularly suitable for dynamic pressure monitoring in hydraulic control systems. Compared with traditional strain gauge sensors, this model can still maintain excellent signal linearity within the medium temperature range of -30~+85℃.


It is worth noting that Domestic Industrial 2088 Pressure Transmitter OPT8250 Diffused Silicon 2088 Pressure Sensor also uses 316 stainless steel as the wetted material, demonstrating good compatibility in corrosive media measurement in the petrochemical industry. Both feature a fast response characteristic of ≤5 milliseconds, which is especially important for scenarios requiring real-time feedback such as power station inspections.


Measured Data from Typical Application Scenarios


Test EnvironmentMeasuring RangeStability PerformanceApplicable Model Reference
Air Compressor Storage Tank0-1.6MPa±0.1%FS/yearGPD-GPD10/OPT8250
Constant Pressure Water Supply Pipeline Network0-2.5MPa±0.08%FS/yearPS6000-CR Series
Chemical Reactor0-10MPa±0.15%FS/yearMBS1900-064G Series

Key Technical Points in Operation and Maintenance


Installation and Commissioning Specifications


Special attention should be paid to sealing treatment for the threaded installation of model PT124B-210-100MPa-M20:


  • Use M20×1.5 standard threads with PTFE sealing tape
  • Avoid mechanical overload impact exceeding 300MPa
  • When using three-wire wiring, ensure that the 24V power supply fluctuation does not exceed ±5%

For CS-m series products, the built-in zero point ±8% adjustment function can effectively compensate for static pressure errors caused by the installation position. In building automation systems, it is recommended to work with a display meter to achieve on-site visual calibration.


Troubleshooting Guide


When signal drift occurs in the GT-V model, troubleshooting should be carried out according to the following steps:


  1. Check whether the medium temperature exceeds the range of -30~+85℃
  2. Measure whether the supply voltage is stable within the 9-36VDC range
  3. Use a standard pressure source to recalibrate zero point/full scale

Horizontal Comparison of Mainstream Market Models


Comparison of JYB-KO-HAG and GPTJG-BSCHX in metallurgical industry applications:


  • Response speed: HAG series 5ms vs BSCHX series 8ms
  • Interface options: the former comes standard with G1/2 male thread, while the latter optionally offers M12×1
  • Cost performance: PB-CNM1 can reduce costs by 15% in bulk procurement

Experimental data shows that Domestic Industrial 2088 Pressure Transmitter OPT8250 Diffused Silicon 2088 Pressure Sensor still performs 2 percentage points better in stability than imported similar products when measuring ultra-high pressure at 250MPa, thanks to its special temperature compensation algorithm.


Procurement Decision Support Plan


According to the special requirements of flow control equipment, it is recommended to evaluate from the following dimensions:


Key MetricsConventional RequirementsHarsh Operating ConditionsRecommended Models
Medium corrosiveness304 Stainless Steel316L Stainless SteelOPT8250/GPD-GPD10
Explosion-Proof RequirementsIP65 protectionIntrinsically Safe TypeMBS1900-064G6601
Signal Transmission4-20mAWith HART ProtocolPS6000-CR-BZ

Professional Technical Support and After-Sales Service


Xi'an Shenghongchuang Instrumentation Co., Ltd. provides all diffused silicon sensors with:


  • 18-month extended warranty period
  • On-site calibration technical training
  • 48-hour emergency response mechanism

For special scenarios such as turbo-generator units, customized range modification services can be provided to ensure seamless integration with DCS systems.


Summary of Industry Application Value


Through continuous technological iteration, diffused silicon pressure transmitters have formed significant advantages in fields such as liquid level control and process inspection:


  1. Improve measurement efficiency by 30% compared with traditional technology
  2. Reduce system maintenance frequency by 50%
  3. Multiple output signals are compatible with existing PLC systems

Contact our technical consultants immediately to obtain customized pressure monitoring solutions and improve the precision and reliability of your process control.

Submit