As a core component of industrial automation control, the FST800-501P341G-400B pressure transmitter uses diffused silicon sensor technology to accurately measure liquid and gas pressure. This tutorial provides a detailed analysis of the installation specifications, commissioning steps, and common troubleshooting methods for this model, helping technical evaluation personnel quickly master the operational essentials of this DG1300-BZ-A-2-4/AF series product and ensuring the accuracy and stability of pressure monitoring in industrial sites.
The FST800-501P341G-400B pressure transmitter adopts diffused silicon piezoresistive sensing technology. By diffusing impurities onto a single-crystal silicon chip to form a Wheatstone bridge, when pressure is applied, the deformation of the silicon diaphragm causes resistance changes, ultimately outputting a standard 4-20mA signal. Compared with traditional capacitive or ceramic sensors, it features high accuracy of ±0.1%FS, long-term stability of 0.01%FS/year, and wide temperature compensation capability from -40~125℃. Xi'an Shenghongchuang Instrument Co., Ltd.'s diffused silicon sensors have passed ISO 9001 quality management system certification, and their core parameters comply with the national standard GB/T 17614.3-2013 for transmitters used in industrial process control systems.
1.Mechanical installation: When using the M20×1.5 threaded interface, a copper gasket seal is required, and the installation torque should be controlled within the range of 35-45N·m. For products in the same series such as PD50-AB100BM20M4B, vertical installation is recommended to avoid medium deposition affecting measurement accuracy.
2.Electrical connection: The power cable should use shielded twisted pair wire (AWG18-22), with grounding resistance less than 4Ω. The FST800-501P341G-100B model supports HART protocol communication. During wiring, ensure correct polarity. The typical wiring diagram is as follows:
1.Zero calibration: Under no-pressure conditions, adjust the Zero parameter through the handheld terminal to make the output 4mA. For the JYB-JYB model, special attention should be paid to performing calibration when the medium temperature is stabilized at 25±5℃.
2.Range calibration: Apply full-scale pressure (400Bar) and adjust the Span parameter until the output is 20mA. For low-pressure models such as FST800-501P341G-10B, it is recommended to use a piston pressure gauge as the standard source, with accuracy better than 0.05 class.
Problem phenomenon: Large output signal fluctuation
Troubleshooting steps:
1. Check whether there are air bubbles or blockage in the pressure guide tube of the JVPL-JVPL16 model
2. Measure whether the power supply voltage fluctuates within the 12-36VDC range
3. Use the TK-509-10 tester to detect sensor impedance (the normal value should be 350Ω±10%)
For models with special interfaces such as BAR-ZZAZ, the following parameters need to be considered重点: