News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

EDYBT-49 Pressure Transmitter Troubleshooting Manual: 7 Typical Solutions for Diffused Silicon Sensor Issues
Added to Favorites:125

As key equipment in industrial automation, the EDYBT-49 pressure transmitter directly affects production safety when its diffused silicon sensor fails. Focusing on 7 major typical problems, this article starts with the fault phenomena of models such as CEMPX215-GATCA1 and KYB18G07M1P4C3-I, and provides professional solutions for diffused silicon liquid and gas pressure sensors to help equipment maintenance personnel quickly diagnose and handle issues, ensuring the stable operation of the flow control system.


Technical Principles and Industry Applications of Diffused Silicon Sensors


Diffused silicon pressure sensors use the semiconductor piezoresistive effect principle. When the pressure of the measured medium acts on the sensitive element, the silicon diaphragm deforms, causing changes in the resistance value of the Wheatstone bridge, and outputs a standard signal after amplification by transmitter circuits such as EDYBT-49. In flow control fields such as petrochemicals and electric power energy, models such as BAR-GP1 and CS-PT1200V are widely used because their measurement accuracy reaches 0.1%FS. The KYB-Z04 series products of Xi'an Shenghongchuang Instrument Co., Ltd. have passed ISO9001 certification, and their temperature compensation technology can ensure stability under working conditions of -40℃~125℃.


Diagnosis and Solutions for 7 Typical Faults


1. Zero Drift Issue (Taking CEMPX215-GATCA1 as an Example)


Phenomenon: the output signal deviates from 4mA under no-pressure conditions. Handling steps: ① disconnect the power supply and check whether the wiring diagram complies with the requirements of the ZWP-L61-K manual; ② use the HQ-HQ1002 calibrator for zero-point calibration; ③ if the drift continues, the sensor chip needs to be replaced. Preventive measures: perform regular verification and avoid mechanical vibration and impact.


2. Full-Scale Output Abnormality (BSCYG9010-1.0 Model)


When the CFUEIIIERC1 display value remains at 20mA, first check whether the measurement range is exceeded, and then use a multimeter to test the supply voltage (standard 24VDC±10%). The KYB18G07M1P4C3-I transmitter provided by Xi'an Shenghongchuang has a built-in overload protection function, which can effectively prevent such problems.


Fault TypeApplicable ModelsSolutionsRequired Tools
Signal interferenceCS-PT1200VInstall shielded cable/magnetic ringSpectrum analyzer
Diaphragm blockageBAR-GP1Chemical cleaning or replacement of the isolation diaphragmUltrasonic cleaning machine

Procurement Selection and Standard Certification Guide


When selecting diffused silicon pressure transmitters such as EDYBT-49, attention should be paid to: ① accuracy class (0.2 class/0.5 class); ② explosion-proof certification (Ex ia IIC T6); ③ medium compatibility (refer to EN 837-1 standard). Xi'an Shenghongchuang's CFUEIIIERC1 series has also obtained CE and SIL certifications, and the threaded interface complies with the G1/2" DIN 3852 standard, making it suitable for corrosive gas measurement.


Why Choose Xi'an Shenghongchuang


As a high-tech enterprise in Xixian New Area, we provide: ① 15 years of R&D experience in diffused silicon sensors; ② 72-hour emergency service response; ③ free wiring diagrams and verification procedures for products such as KYB-Z04. Call 029-8456XXXX now to obtain the EDYBT-49 technical manual and customized solutions.


FAQ Frequently Asked Questions


Q: What is the difference between diffused silicon and ceramic sensors?
A: Diffused silicon sensors (such as CEMPX215-GATCA1) offer higher accuracy (0.1% vs 0.5%), but ceramic sensors (improved BSCYG9010-1.0 model) have stronger corrosion resistance. The specific selection needs to be determined according to the characteristics of the medium.


Q: How can it be determined whether a sensor needs calibration?
A: When the HQ-HQ1002 calibrator detects that the output error of the CS-PT1200V exceeds 1.5 times its accuracy class, calibration must be carried out according to the JJG 882-2019 procedure.

Submit