When purchasing the DQ-805 pressure transmitter,price is an important consideration. This article provides an in-depth analysis of the reasons for quotation differences among diffused silicon sensors,compares the cost performance of models such as HM20G-1-A1-F1-W2,M-M5176,and HT-PD,and helps you find the best procurement channels for genuine DG1300-BZ series and PT124B-210 high-quality pressure transmitters.
In the current industrial sensor market,diffused silicon pressure transmitters hold a significant share thanks to their stability and accuracy. Prices of products represented by the DQ-805 and DG1300-BZ series can vary by 30%-50%,mainly due to the following factors:
Comparison based on measured data shows that the DG1300-BZ-C-2-0.6 achieves a linearity of ±0.1%FS in the 0.6MPa range,outperforming similar products. However,the M-M5176 shows a temperature drift of 0.05% during gas pressure measurement,so it is recommended to choose the DQ-805 model with temperature compensation for high-temperature operating conditions.
Accuracy class:the genuine DG1300-BZ series can reach class 0.075,while mixed products on the market are usually only class 0.2. If you need to measure both tension and compression force,you may consider the Chinese-made weighing sensor XYL-1 tension-compression S-type stainless steel weighing sensor,with a comprehensive accuracy of 0.02~0.03.
The survey shows that the quotation for DG1300-BZ-B-2-1.6 from authorized distributors is 8-12% higher than that from unofficial channels,but complete ISO9001 quality traceability documents are provided. It is recommended to verify genuine products in the following ways:
Q:Does the HT-PD sensor fluctuate during liquid measurement?A:This is usually caused by air pockets at the installation position. It is recommended to install an exhaust valve at the high point of the pipeline,or switch to a DQ-805 model with damping adjustment.
Q:How to determine whether a diffused silicon sensor needs to be replaced?A:When the zero drift exceeds 0.5% of the range or the insulation resistance is <100MΩ(a typical failure seen after 3 years of use of the M-M5176),it should be replaced in time.
For dynamic weighing scenarios such as crane scales,it is recommended to use the Chinese-made weighing sensor XYL-1 together. Its S-type structure can withstand both tension and compression force,and its operating temperature range of -20℃~+65℃ meets the requirements of most industrial environments. This product has passed a 150% safe overload test and can form a complete measurement system with the AST-K000 pressure transmitter.