News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

CY-H Pressure Transmitter Technical Performance Analysis:How Is Industrial-Grade Accuracy Achieved?
Added to Favorites:125

Technical Performance Analysis of CY-H Pressure Transmitter:How Is Industrial-Grade Accuracy Achieved?

In the field of industrial automation,the CY-H pressure transmitter has become the preferred choice for critical equipment due to its outstanding technical performance. This article provides an in-depth analysis of the accuracy achievement principles of diffused silicon liquid and gas pressure sensors,covering the technical features of models such as PD50-GB10CM20M4M and FST800211G3451-25B,helping operators fully understand key points for product installation,specifications and maintenance.

I. Core Technical Principles of Diffused Silicon Pressure Sensors

The core of a diffused silicon pressure sensor lies in the Wheatstone bridge structure on its silicon diaphragm. When medium pressure acts on the 316 stainless steel isolation diaphragm,it is transmitted through silicone oil to the silicon sensing element,causing a change in resistance value. This change is converted by the ASIC signal conditioning circuit into a standard 4-20mA output,achieving low temperature drift characteristics of ±0.05%FS/℃. Taking the Domestic General-Purpose Pressure Transmitter LD183Q Compact Rod-Type Pressure Sensor as an example,it uses laser calibration technology to ensure Class 0.25 accuracy,with a temperature compensation range covering -20~85℃,making it especially suitable for scenarios with large temperature differences such as power station inspections.

II. Comparative Analysis of Key Performance Indicators

ModelAccuracy ClassOverload CapacityMedium TemperatureTypical Applications
CY-HClass 0.252 times range-30~85℃Petrochemical Process Control
PD50-GB10CM20M4MClass 0.5300MPa-20~70℃Hydraulic System Monitoring
FST800211G3451-25BClass 1.0150%FS-10~60℃Building Automation

It is worth noting that models such as HDA4445-A-250-Y00 use 316L stainless steel wetted parts,improving corrosion resistance by 30%,and delivering outstanding performance in harsh environments such as seawater desalination.

III. Five Professional Recommendations for Installation and Commissioning

  1. Sealing tape should be used during threaded installation to avoid leakage at the G1/2 male thread interface
  2. Avoid installing models such as STZ2-3 at pipe bends to prevent vortex interference
  3. For PTG-PTG702 transmitters,it is recommended to add a pulse damper to eliminate water hammer effects
  4. The cable entry of RC-RC301 should be installed facing downward to prevent condensate accumulation
  5. During commissioning,perform zero-point calibration first,then adjust the range to within ±20%

A case study from a metallurgical enterprise shows that after the SAM-K pressure transmitter was correctly installed,its annual stability improved from ±0.3%FS to ±0.1%FS.

IV. Industry Application Solutions

In thermal power units,the CPS-C pressure transmitter needs to be used with heat sinks to ensure long-term stability at a medium temperature of 85℃. The Domestic General-Purpose Pressure Transmitter LD183Q,with its 1-5VDC three-wire output,is especially suitable for direct connection with PLC systems. For locomotive braking systems,it is recommended to select models with a rise time of ≤5ms to ensure real-time response.

V. In-Depth Analysis of Common Questions

Q:How can you determine whether a diffused silicon sensor has failed?
A:When HDA4445-A-100-Y00 shows output signal fluctuation >1%FS,silicone oil leakage may be present;if zero drift exceeds ±8% of the range,the diaphragm should be checked for deformation.

Q:How should models be selected for different media?
A:For corrosive media,the CPS-C series made of 316L stainless steel is preferred;for viscous media,PD50-GB10CM20M4M with a flush diaphragm is recommended.

The STZ2-3 pressure transmitter produced by an ISO9001-certified manufacturer can achieve a mean time between failures of up to e5 ten thousand hours,significantly higher than the industry average.

To obtain the complete technical manual or customized solutions for the CY-H pressure transmitter,please contact our engineering team for professional consultation.

Submit