News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

CYYZ11 Pressure Transmitter Test Report: The Secret to Zero Drift After 3000 Hours of Continuous Operation
Added to Favorites:125
CYYZ11 Pressure Transmitter Field Test Report: The Secret to Zero Drift After 3000 Hours of Continuous Operation

Introduction

In the field of industrial automation, the stability of pressure transmitters directly affects production safety and efficiency. The newly launched CYYZ11 pressure transmitter from Xi'an Shenghongchuang Instrument Co., Ltd. demonstrated zero-drift characteristics after a 3000-hour continuous operation test, redefining industry reliability standards. This article will provide an in-depth analysis of its core technologies and conduct comparative tests with mainstream models such as ZPM310 and ZRN201B, providing key decision-making support for technical evaluators.


Analysis of the Core Technologies of the CYYZ11 Pressure Transmitter

The CYYZ11 pressure transmitter adopts Xi'an Shenghongchuang's patented third-generation silicon micromelting technology. Its core sensor components achieve molecular-level structural reorganization through a high-temperature melting process, enabling the sensor to maintain annual stability of ±0.05%FS within the operating range of -40℃~125℃. Compared with the diffused silicon technology used in the traditional ZPM310 pressure transmitter, its temperature drift coefficient is reduced by 60%.

This product innovatively adopts a triple redundant compensation system:

  • Temperature compensation: built-in high-precision Pt1000 thin-film resistor array, achieving 0.01℃ resolution
  • Stress compensation: patented mechanical decoupling structure (Patent No. ZL202010XXXXXX.X) eliminates the impact of installation stress
  • Time drift compensation: adaptive algorithm based on machine learning, automatically calibrates the zero point every 8 hours

Measured data shows that during 3000 hours of continuous monitoring in the petrochemical industry, the output signal fluctuation range of the CYYZ11 was only ±0.02mA, far better than the industry average level of ±0.1mA for the ZRN201B pressure transmitter.


Performance Comparison Test with Mainstream Models

We conducted comparative tests on 6 mainstream pressure transmitters in an ISO/IEC 17025 accredited laboratory environment:

ModelAccuracy ClassTemperature effect (%FS/10℃)3000-hour drift amountMTBF(hours)
CYYZ110.075±0.020150,000
ZPM3100.1±0.05±0.08%100,000
ZRN201B0.2±0.1±0.15%80,000
RF-BPS3160.1±0.03±0.05%120,000

Test conditions: medium was water, pressure cycle range 0-10MPa, temperature cycle -20℃~85℃, vibration conditions 5-2000Hz/5Grms. The data shows that the CYYZ11 is significantly superior to similar products such as the ZRN209 pressure transmitter in terms of long-term stability.


Analysis of Key Application Scenarios

1. Petrochemical Field

In the catalytic cracking unit of a refinery in Shaanxi, after replacing the original SIN-P300 pressure transmitter with the CYYZ11, the annual maintenance frequency was reduced from 23 times to 3 times. Its resistance to sulfide stress corrosion has passed NACE MR0175 certification, making it particularly suitable for measuring sulfur-containing media.

2. Power Industry

Compared with the traditional MBC-1 pressure transmitter, the CYYZ11 demonstrates better resistance to water hammer impact in steam pipeline pressure monitoring. Use in a 600MW unit at a power plant has proven that its response time is shortened to 8ms, meeting the requirements of the ASME B40.100 standard for Class A transmitters.

3. Water Treatment Systems

To address the common diaphragm scaling problem of the ZR804 pressure transmitter in wastewater treatment, the CYYZ11 adopts a 316L stainless steel + polytetrafluoroethylene composite diaphragm design. In comparative testing at a wastewater treatment plant in Xi'an, it operated continuously for 18 months without any loss of accuracy.


Industry Standard Compliance Verification

The CYYZ11 pressure transmitter has passed the following certifications:

  • GB/T 17614.1-2015 Transmitters for industrial process control systems
  • IEC 61508 SIL2 functional safety certification
  • EMC test: EN 61326-1:2013 Class A
  • Explosion-proof certification: ATEX II 1G Ex ia IIC T6 Ga

Compared with the RS-YB01 pressure transmitter, its newly added online self-diagnostic function meets the requirements of the VDI/VDE 2650 standard and can monitor 12 parameters in real time, including diaphragm integrity and circuit health.


Conclusion and Recommendations

Through innovative silicon micromelting technology and a triple compensation system, the CYYZ11 pressure transmitter from Xi'an Shenghongchuang Instrument Co., Ltd. has achieved industry-leading long-term stability. For applications requiring highly reliable monitoring, such as auxiliary systems in nuclear power plants where the SIN-P300Z pressure transmitter is currently used, the CYYZ11 can provide a better solution.

As a high-tech enterprise specializing in the R&D of flow control equipment, we recommend that technical evaluators focus on the following:

  1. In environments with large temperature fluctuations, give priority to temperature impact indicators
  2. For long-term continuous operation scenarios, verify stability data of more than 3000 hours
  3. In corrosive media environments, review material compatibility certifications

If you need a detailed comparison report between the CYYZ11 and your existing pressure transmitters such as ZPM310 and ZRN201B, or would like to arrange on-site testing, please contact our technical team for a customized solution.

Submit