Pressure Transmitter Manufacturer
Consultation hotline:15529283736
News Center
—— NEWS CENTER ——
Xi'an Shenghongchuang Instrument Co., Ltd.
Contact: Mr. Zhang
Mobile: 15529283736
Email: shc-sensor@qq.com
Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province
In the field of pipeline network monitoring,BLS ultrasonic transmitters demonstrate 5 core advantages with the excellent performance of their SCL-80,SCL-60 and other series products。As the flagship products of Xi'an Shenghong Chuang Instrument Co., Ltd.,these wall-mounted ultrasonic flow sensors not only offer high accuracy and strong stability,but also adapt to complex operating conditions,providing technical evaluation personnel with reliable flow monitoring solutions。This article will provide an in-depth analysis of their outstanding performance in practical applications。
With the acceleration of urbanization,the scale of pipeline network systems such as water supply and heating continues to expand,and traditional mechanical flowmeters have exposed problems such as accuracy degradation and high maintenance costs during long-term operation。According to statistics from the International Water Association(IWA),approximately 35% of pipeline networks worldwide experience leakage,among which insufficient performance of monitoring equipment is an important contributing factor。BLS series ultrasonic transmitters use the transit-time measurement principle,and through the acoustic transmission technology of models such as SCL-80 and SCL-62,achieve a measurement accuracy of ±0.5%,far exceeding the requirements of the ISO 4064 standard。This non-contact measurement method is especially suitable for monitoring sewage pipeline networks containing particulate matter,avoiding the risk of impeller jamming in traditional turbine flowmeters。
BLS series products adopt a 316 stainless steel housing design,with a protection rating of up to IP68,and can operate stably at ambient temperatures from -30℃ to 85℃。Comparative tests show that the SCL-60 model can still maintain continuity of flow data acquisition in slurry pipelines containing 30% solid particles,a feature that is difficult to achieve with traditional Domestic High-Temperature Pressure Transmitter ZP-111 Diffused Silicon Pressure Sensor。Its adaptive signal processing algorithm can automatically compensate for measurement errors caused by changes in fluid temperature and density。
Unlike single flow monitoring devices,models such as BYLDN-1-B can synchronously collect data including flow velocity,flow rate,totalized flow,and medium temperature,and upload it to the monitoring system via the MODBUS RTU protocol。This multifunctional feature significantly reduces the hardware complexity of pipeline network monitoring systems。After a provincial water supply group adopted DCT1258 transmitters,the number of deployed sensors was reduced by 42%,and annual maintenance costs decreased by 28%。
The wall-mounted SY-CSB-6000 supports external clamp-on installation,without the need to cut pipelines or shut down the system。Technical evaluation reports indicate that its installation time is only 1/5 that of a flanged flowmeter,making it especially suitable for renovation projects of aging pipeline networks。The matching Bluetooth commissioning APP can display signal quality curves in real time,improving on-site calibration efficiency by more than 60%。
BLS products adopt a self-cleaning sensor design。Five-year tracking data shows that the zero drift of the SCL-80 does not exceed 0.1%FS/year。This is similar to the Domestic High-Temperature Pressure Transmitter ZP-111 Diffused Silicon Pressure Sensor,which uses laser marking to ensure traceability,and both demonstrate Xi'an Shenghong Chuang's strength in precision manufacturing。Its core components have passed a 2000-hour accelerated aging test,with an MTBF indicator reaching 100,000 hours。
The DCT1158C model has a built-in AI diagnostic algorithm,which can identify abnormal operating conditions such as empty pipes and bubble accumulation and trigger alarms。An application case from a petrochemical enterprise shows that this function helped detect pipeline sedimentation issues 14 days in advance,avoiding an equipment shutdown accident that could have caused a loss of 3 million yuan。
For high-temperature and high-pressure operating conditions,it is recommended to give priority to the combined solution of SCL-62 and SY-CSB-6000;for conventional water supply pipeline networks,the cost-effective DCT1158C can be selected。It should be noted that the installation position of the ultrasonic transmitter should avoid the downstream side of pump valves by a distance of 10 times the pipe diameter to ensure a stable flow field。Xi'an Shenghong Chuang provides free technical solution design services,and its CNAS-certified laboratory located in Xixian New Area can conduct product performance verification tests。
As a national high-tech enterprise,Xi'an Shenghong Chuang holds 23 patents related to flow measurement,and BLS series products have passed international certifications such as CE and SIL2。We assign a dedicated technical consultant to each project,providing full life-cycle services from model selection and commissioning to data analysis。Contact us now to obtain eligibility for a 72-hour free trial of an SCL-80 sample unit,and our professional technical team will assist you in developing the optimal monitoring solution。
Related Recommendations