This article provides a detailed user guide for the 2302 split-type submersible level transmitter, analyzing the complete process from installation to commissioning, helping purchasers and project managers quickly understand the measuring range, service life, and accuracy characteristics of YH802, YH801, T51A and other series products, and learn how to work in coordination with supporting instruments such as 2301.
Before deploying the 2302 split-type submersible level transmitter, it is necessary to select a suitable model according to the actual operating conditions. The YH802 series is suitable for a measuring range of 0-100 meters water column, and its 316L stainless steel material can withstand highly corrosive media; while the T51A model, with its high accuracy of 0.1%FS, is especially suitable for pure water tank monitoring in the pharmaceutical industry. Before installation, check the interface compatibility of supporting instruments (such as the 2301 display controller), and prepare dedicated mounting brackets and sealing gaskets.
Key preparation work includes:
The probe part of the 2302 transmitter needs to be vertically fixed at the bottom of the container, and a counterweight is used to ensure that the sensor remains parallel to the liquid surface. The advantage of the split-type design is that the transmitter module can be installed in a safe area within 30 meters of the probe, with the specific steps as follows:
Note: The measuring diaphragm of YH802 needs to be cleaned regularly, especially in wastewater treatment applications where fouling should be checked quarterly.
Use shielded twisted pair cable to connect the transmitter and the 2301 supporting instrument, and never reverse the positive and negative power supply terminals. If networked monitoring is required, it is recommended to use the MODBUS-RTU protocol, with the terminal resistor set to 120Ω. Key parameter comparison table:
Perform zero/span calibration through a HART communicator or the supporting instrument menu:
Common troubleshooting: If the YH802 shows signal fluctuation, check the waterproof performance of the cable connector; when the 2301 supporting instrument displays abnormally, the potentiometer parameters should be reissued.
According to the durability test data of 100,000 pressure cycles for the YH801 product, it is recommended to:
The 2302 split-type submersible level transmitter series of Xi'an Shenghongchuang Instrumentation Co., Ltd., through ISO9001-certified production processes and 72-hour aging tests, ensures reliable operation in harsh scenarios such as petrochemical and water treatment. Our engineering team can provide:
Contact our technical consultants now to obtain the white paper Installation Specifications for Split-type Level Gauges, or schedule an on-site commissioning service.