News Center

——  NEWS CENTER  ——

News Center
Contact Us

Xi'an Shenghongchuang Instrument Co., Ltd.

Contact: Mr. Zhang

Mobile: 15529283736
Email: shc-sensor@qq.com

Address: Fortune Building, Sanqiao Street, Xixian New Area, Xi'an, Shaanxi Province

200 Series Wall-Mounted Ultrasonic Flow Sensor: How to address the challenges of flow monitoring in complex environments?
Added to Favorites:125

In complex industrial environments, how do the 200 series wall-mounted ultrasonic flow sensors break through traditional monitoring bottlenecks? Models such as SYTFTDS-100P and TC-SC precisely handle harsh scenarios such as corrosive media and high-pressure pipelines through non-contact measurement technology. This article will provide an in-depth analysis of their anti-interference design principles and on-site application solutions, providing a basis for model selection decisions for technical evaluation personnel.


I. Definition and Overview: The Technological Revolution of Ultrasonic Flow Sensors


As a new generation of flow monitoring equipment, the 200 series wall-mounted ultrasonic flow sensors use the transit-time measurement principle, calculating flow velocity through the time difference of ultrasonic signal propagation in the fluid. Compared with traditional mechanical flowmeters, their outstanding advantages are the absence of moving parts and a maintenance-free design, making them especially suitable for the long-term stable operation of the SYTFTDS-100P model in strong acid and strong alkali environments. The TC-SC series developed by Xi'an Shenghongchuang Instrument Co., Ltd. further integrates DSP digital signal processing technology, with measurement accuracy up to ±0.5%, meeting the highest class requirements of the ISO 12242 international standard for liquid flowmeters.


II. Technical Performance Comparison: Analysis of Core Parameters of Mainstream Models


When evaluating models such as HD-TUF-2000 and ABDT-LCT-S, technical parameters directly affect equipment selection decisions. The comparison table below shows the differences in key performance:


ModelMeasurement AccuracyPressure RatingMedium temperature rangeProtection Rating
GLP-TDS-100H±0.8%4MPa-20℃~120℃IP67
KATflow 200±0.5%6MPa-30℃~150℃IP68

It is particularly worth noting that the UFLO2000 model adopts an automatic acoustic path optimization algorithm, which can effectively address the signal attenuation problem caused by pipeline vibration, a technical feature not available in traditional SEAN series equipment.


III. In-Depth Analysis of Application Scenarios: Solving Challenges in Complex Operating Conditions


In corrosive media monitoring in the chemical industry, the polytetrafluoroethylene probe protective layer of the UFT series sensors can resist the corrosion of 98% concentrated sulfuric acid; while in the food and pharmaceutical fields, more attention is paid to the hygienic design of the GLP-TDS-100H, which is certified to 3-A Sanitary Standards. Actual cases show that after a petrochemical enterprise adopted the TC-SC model, the annual maintenance cost on a DN500 high-pressure steam pipeline was reduced by 67%, and the data drift rate was controlled within 0.2%.


IV. Procurement Guide: Core Evaluation Dimensions for Technical Assessors


For technical decision-makers, in addition to conventional parameters, the following also need to be prioritized:

  • Pipeline material compatibility(carbon steel/stainless steel/glass fiber reinforced plastic, etc.)
  • Signal output diversity(4-20mA/RS485/HART protocol)
  • Installation method flexibility(space requirements for V-method/Z-method installation)
  • Completeness of software configuration tools(such as the Katman analysis software supporting KATflow)

The SYTFTDS-100P solution provided by Xi'an Shenghongchuang Instrument Co., Ltd. includes on-site survey services and can customize sensor spacing according to the user's pipeline operating conditions to ensure optimal signal reception quality.


V. Common Misconceptions and Professional Answers


Q: Is the ultrasonic flowmeter affected by fluid conductivity?
A: Unlike electromagnetic flowmeters, ultrasonic models such as ABDT-LCT-S are completely unrestricted by conductivity and can measure insulating media such as diesel.


Q: How does the 200 series perform in liquids containing bubbles?
A: The multi-pulse emission technology equipped in HD-TUF-2000 can automatically identify and filter bubble interference signals, still maintaining ±1.2% accuracy under gas-liquid mixed operating conditions.


VI. Why Choose Xi'an Shenghongchuang Instrument


As a national high-tech enterprise, we have accumulated 15 years of technical expertise in the field of fluid measurement, and the 200 series products have passed international certifications such as CE and SIL2. For special operating conditions, we provide:

  1. 72-hour rapid prototype testing service
  2. Three-year extended warranty period
  3. Customized sensor coating solutions

Contact our technical engineers now to obtain personalized model selection reports and on-site testing solutions for models such as SYTFTDS-100P and TC-SC.

Submit